NEW EATON Circuit Breaker FAZ-C13/1-NA 1 Pole 13 Amp 277 VAC / 48 VDC FAZ Din C
Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042). 277 Y V AC. Rated current [In]. Product range. IEC/EN 60947-2; EN 45545-2; IEC 61373; UL 489; CSA-C22.2 No. 5-09; CE marking.
Schneider Electric TeSys Deca Motor Circuit Breaker 9 to 13A GV3P13
Messages are responded to Monday-Friday 8 AM to 4 PM Central Time. Please message us for additional photos or details. If you would like expedited shipping, please message us BEFORE placing the order so we can add the shipping service/cost to the listing. We can ship on your FedEx or UPS account- message us BEFORE placing the order or leave a buyer’s note on the order with your account number. We do not use USPS. International orders are shipped using the eBay International Shipping Program. If you would like us to ship internationally with a different service, message us BEFORE placing the order. Poles description3PNetwork typeACUtilisation categoryAC-3 IEC 60947-4-1Network frequency50/60 Hz IEC 60947-4-1Fixing mode35 mm symmetrical DIN rail clippedPanel screwed with 3 x M4 screws)Motor power kW5.5 kW 400/415 V AC 50/60 Hz7.5 kW 500 V AC 50/60 Hz11 kW 690 V AC 50/60 HzBreaking capacity100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-250 kA Icu 440 V AC 50/60 Hz IEC 60947-212 kA Icu 500 V AC 50/60 Hz IEC 60947-26 kA Icu 690 V AC 50/60 Hz IEC 60947-2[Ics] rated service short-circuit breaking capacity100 % 230/240 V AC 50/60 Hz IEC 60947-2100 % 400/415 V AC 50/60 Hz IEC 60947-2100 % 440 V AC 50/60 Hz IEC 60947-250 % 500 V AC 50/60 Hz IEC 60947-250 % 690 V AC 50/60 Hz IEC 60947-2Control TypeRotary handleLine Rated Current13 AThermal protection adjustment range9…13 A IEC 60947-4-1Magnetic tripping current182 A[Ith] conventional free air thermal current13 A IEC 60947-4-1[Ue] rated operational voltage690 V AC 50/60 Hz IEC 60947-2[Ui] rated insulation voltage690 V AC 50/60 Hz IEC 60947-2[Uimp] rated impulse withstand voltage6 kV IEC 60947-2Phase failure sensitivityYes IEC 60947-4-1Suitability for isolationYes IEC 60947-1Power dissipation per pole8 WMechanical durability50000 cyclesElectrical durability50000 cycles AC-3 415 V InRated dutyContinuous IEC 60947-4-1Tightening torque44.25 lbf.in (5 N.m) screw clamp terminalWidth2.17 in (55 mm)Height5.20 in (132 mm)Depth5.35 in (136 mm)Net Weight2.12 lb(US) (0.96 kg)colorDark grey
Schneider GV3P13 TeSys Motor Circuit Breaker 3P 9-13A 690V Thermal Magnetic
Schneider Electric GV3P13 TeSys Deca Motor Circuit Breaker 3P 9-13A Thermal-Magnetic — Made in France. Schneider Electric TeSys Deca GV3P13 is a 3-pole thermal-magnetic motor circuit breaker with adjustable 9-13 A overload protection.
2 Qty CIEE SB8 250V 13A Circuit Breaker Panel Mount Power Overload Safety Switch
2 Qty CIEE SB8 250V 13A Circuit Breaker Panel Mount Power Overload Safety Switch Listing is for 2 Quantity as seen in pics. All are new.
EATON HEINMANN FAZ-C13/1-NA-SP AC DC DIN RAIL CIRCUIT BREAKER 13A A AMP 48 V 277
13A 48VDC 277VAC. DIN RAIL NOT INCLUDED IN PICTURES, TO SHOW APPLICATION ONLY.
Cutler Hammer WMS2C13 Circuit Breaker Supplementary Protector 13 Amp 2 Pole 415V
New item condition. Original box not included. Industrial surplus.