Sensata Airpax 30 amp circuit breaker AP-12-1-42F-302 240 V 5925-01-059-9783

Sensata Airpax 30 amp circuit breaker AP-12-1-42F-302240 V This item is new and unused, I opened one to photograph, as you can see these are old new stock from a military release. Here is The Tech Info from the internet.NameValueBODY STYLEMULTIPOLE-SINGLE ACTUATOR TYPEBUSHING LENGTH0.380 INCHES MAXIMUMBODY LENGTH1.500 INCHES MAXIMUMBODY WIDTH1.250 INCHES MAXIMUMCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.844 INCHES MINIMUM AND 0.906 INCHES MAXIMUMCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUMNONTURN DEVICE RADIUS0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUMNONTURN DEVICE LENGTH0.063 INCHES MINIMUM AND 0.125 INCHES MAXIMUMNONTURN DEVICE DIAMETER0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUMFRAGILITY FACTORMODERATELY RUGGEDMOUNTING SURFACE TO TERMINAL END DISTANCE1.780 INCHES MAXIMUMPOLE QUANTITY2ARC QUENCHING METHODMAGNETIC BLOWOUTMOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING W/PANEL SEALSTORAGE TYPEGENERAL PURPOSE WAREHOUSESPECIAL HANDLING FEATUREMAGNETICTHREAD QUANTITY PER INCH32MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE3.0 AMPERES AC ALL LOCATIONSOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC ALL LOCATIONSMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 AC ALL LOCATIONSCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONSTRIP RELEASE METHODMAGNETIC ALL LOCATIONSTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONSULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0 ALL LOCATIONSRESET METHODMANUALMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREEMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLEACTUATOR FUNCTIONTRIP-RESETACTUATOR POSITION DESIGNATIONBETWEEN POLE ONE AND TWOINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONSNOMINAL THREAD SIZE0.375 INCHESTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.900 MINIMUM AT 200 PCT AND 4.000 MAXIMUM AT 200 PCT ALL LOCATIONSINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDHERMETICALLY SEALED AND SHOCK RESISTANT AND VIBRATION RESISTANTSPECIAL FEATURESINERTIAL DELAY INCLUDED ON ITEMFREQUENCY IN HERTZ400.0 ALL LOCATIONSTHREAD SERIES DESIGNATORUNEFTERMINAL TYPE AND QUANTITY4 WIRE HOOKFIIGINCDescriptionDetailA030A000136CIRCUIT BREAKERA DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO “BREAKER” ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER