GV2ME16 9-14A TeSys GV2 Manual Starters and Protectors SCHNEIDER NEW SEALED BOX

MainrangeTeSysproduct nameTeSys GV2device short nameGV2MEproduct or component typeCircuit breakerdevice applicationMotortrip unit technologyThermal-magneticComplementarypoles description3Pnetwork typeACutilisation categoryAC-3 conforming to IEC 60947-4-1Category A conforming to IEC 60947-2network frequency50/60 Hz conforming to IEC 60947-4-1fixing modeClipped on 35 mm symmetrical DIN railScrewed on panel (with adaptor plate)operating positionAny positionmotor power kW11 kW at 690 V AC 50/60 Hz9 kW at 690 V AC 50/60 Hz7.5 kW at 500 V AC 50/60 Hz5.5 kW at 400/415 V AC 50/60 Hzbreaking capacity3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-215 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-28 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-26 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-250 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-250 %at 440 V AC 50/60 Hz conforming to IEC 60947-275 % at 500 V AC 50/60 Hz conforming to IEC 60947-275 %at 690 V AC 50/60 Hz conforming to IEC 60947-2control typePush-button[In] rated current14 Athermal protection adjustment range9…14 Amagnetic tripping current170 ASystem Voltage690 V AC 50/60 Hz conforming to IEC 60947-2[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2[Ith] conventional free air thermal current14 A conforming to IEC 60947-4-1[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2power dissipation per pole2.5 Wmechanical durability100000 cycleselectrical durability100000 cycles AC-3 at 440 Voperating rate25 cyc/hrated dutyContinuous conforming to IEC 60947-4-1connections – terminalsScrew clamp terminals 2 cable(s) 1…6 mm² solidScrew clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable endScrew clamp terminals 2 cable(s) 1…4 mm² flexible with cable endtightening torque1.7 N.m on screw clamp terminalssuitability for isolationYes conforming to IEC 60947-1phase failure sensitivityYes conforming to IEC 60947-4-1height3.5 in (89 mm)width1.77 in (45 mm)depth3.08 in (78.2 mm)product weight0.57 lb(US) (0.26 kg)EnvironmentstandardsEN 60204IEC 60947-1IEC 60947-2IEC 60947-4-1NF C 63-120NF C 63-650NF C 79-130UL 508VDE 0113VDE 0660CSA C22.2

G.E. Main Breaker Indoor Load Center 100 Amp 20-Space 20-Circuits No Cabinet

The G.E. Main Breaker Indoor Load Center is a 100 Amp, 20-Space, 20-Circuit unit suitable for interior use in a utility/laundry room. It features a copper bus for enhanced conductivity and includes three 20 Amp single-pole breakers. With a maximum amperage of 100 A, this rotary knob-controlled panel has a voltage range of 201-250 V AC and operates at a temperature of 60 °C (140 °F). Made of galvanized steel, this main breaker from GE is designed for commercial and residential applications.

**pack Of 10**Square D HOM120PDF Single-Pole Arc Fault Gfi Single Pole**10 Pcs**

This product is a pack of 10 Square D HOM120PDF Single-Pole Arc Fault Gfi circuit breakers, each rated for 120 volts and 20 amps. They are suitable for wall mounting and have a clip-on mounting style. The circuit breakers feature a plug-on neutral design and are compatible with wire gauges ranging from 12 to 10 AWG. The operation method is on/off, and the break time is instantaneous. These breakers are suitable for use in any room of the home and are designed for analog/mechanical control style. With a maximum amperage of 20A, these arc fault circuit breakers offer protection from arc faults in residential electrical systems.