NEW Motor circuit breaker GV2P08 2.5-4.0A manual motor starter with rotary knob

Store CategoriesStore CategoriesU.S. local inventoryAU local inventoryChinese local stockContactorContact kitCircuit breakerContactor coilShunt coilContactor relayOverload relayTime relayMonitoring RelayRelay Module PLCDistribution boxJunction BoxMetal buttonSwitched SocketWaterproof isolating switchAuxiliary switchAutomatic transfer switchOtherNEW Motor circuit breaker GV2P08 2.5-4.0A manual motor starter with rotary knob Product Description main information Product Series TeSys Deca product name TeSys GV2 TeSys Deca product type Motor circuit breaker product short name GV2P Applications Motor protection Trip unit type Thermomagnetic Additional information number of poles 3P Network Type AC use category AC-3 conforms to IEC 60947-4-1 Class AC conforms to IEC 60947-2 Network frequency 50/60 Hz conforming to IEC 60947-4-1 fixed mode 35 mm DIN rail: clipped Panel: screw type (with 2 x M4 screws) Motor power (kW) 1.1 kW at 400/415 V AC 50/60 Hz 1.5 kW at 500 V AC 50/60 Hz 2.2 kW at 690 V AC 50/60 Hz Ability to divide 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50 /60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 Rated operating short-circuit breaking capacity [Ics] 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 control type Rotary handle Rated current [In] 4 A Thermal overload protection setting range 2.5…4 A conforming to IEC 60947-4-1 Electromagnetic trip current 51 A Conventional thermal current [Ith] 4 A conforming to IEC 60947-4-1 Rated working voltage [Ue] 690 V AC 50/60 Hz conforming to IEC 60947-2 Rated insulation voltage [Ui] 690 V AC 50/60 Hz conforming to IEC 60947-2 Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60947-2 phase loss sensitivity Is compliant with IEC 60947-4-1 isolation function Applies to IEC 60947-1 § 7-1-6 power consumption per pole 2.5W Payment PolicyShipping PolicyReturns PolicyAbout usPayment Policy We accept paypal, Google Pay, Apple Pay, VISA MASTERCARD, American Express All major credit cards are accepted through secure payment processor PayPal. We ship to your eBay or Paypal address. Please make sure your eBay and Paypal address is correct before you pay Shipping PolicyWe ship to your eBay or Paypal address. Please make sure your eBay and Paypal address is correct before you pay. Items will be shipped within 1-3 business day when we received payment. Delivery time depends on destination and other factors; International buyers please note: Import duties, taxes and charges are not included in the item price or shipping charges. These charges are buyer’s responsibility. We will try our best to reduce the risk of the custom duties. Custom Duties & Taxes: Import duties, taxes, and charges are not included in the item price or postage cost. These charges are the buyer’s responsibility. Ship to Europea under 150 Euro will used our IOSS number for VAT , over 150 Euro please offer your VAT number after your paid , Ship to South American please offer your RUC/NIT Number before shipment Country/Region of Manufacture:CHINA Point of origin:CHINA SHANGHAI Logistics mode: according to the logistics policy Returns Policy No reason to return or exchange within 30 days,The freight shall be borne by the seller Once your return has been received by the warehouse and it complies with our returns policy, we will refund you by your original payment method. Please be aware that payments can take up to 7 working days to process depending on your bank or payment provider. Returned items will be refunded excluding the original cost of shipping. After we have issued the refund, it will take up to 3 business days for the funds to be placed back on your credit card or Paypal account.About usCopyright © 2021 Dianxiaomi

NEW GV2P14 Motor circuit breaker 6-10A manual motor starter with rotary knob

Store CategoriesStore CategoriesU.S. local inventoryAU local inventoryChinese local stockContactorContact kitCircuit breakerContactor coilShunt coilContactor relayOverload relayTime relayMonitoring RelayRelay Module PLCDistribution boxJunction BoxMetal buttonSwitched SocketWaterproof isolating switchAuxiliary switchAutomatic transfer switchOtherGV2P14 Motor circuit breaker MANUAL STARTER 690VAC 6-10A otary knob controled Product Description main information Product Series TeSys GV2 Product Series TeSys TeSys Deca product short name GV2P product name TeSys GV2 TeSys Deca product type Breaker Applications Motor protection trip unit type Thermomagnetic Additional information number of poles 3P Network Type AC use category AC-3 conforming to IEC 60947-4-1 Class AC conforming to IEC 60947-2 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixed mode 35 mm DIN rail: clipped Panel: screw type (with 2 x M4 screws) Operating position Any position Motor power (kW) 3 kW at 400/415 V AC 50/60 Hz 5.5 kW at 690 V AC 50/60 Hz 5 kW at 500 V AC 50/60 Hz breaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50 /60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 Rated short-circuit breaking capacity [Ics] 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 control type Knob Rated current [In] 10A thermal protection adjustment range 6…10A Electromagnetic tripping current 138A Rated working voltage [Ue] 690 V AC 50/60 Hz conforming to IEC 60947-2 Rated insulation voltage [Ui] 690 V AC 50/60 Hz conforming to IEC 60947-2 Conventional thermal current [Ith] 10 A according to IEC 60947-4-1 Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60947-2 Power consumption per pole 2.5W Payment PolicyShipping PolicyReturns PolicyAbout usPayment Policy We accept paypal, Google Pay, Apple Pay, VISA MASTERCARD, American Express All major credit cards are accepted through secure payment processor PayPal. We ship to your eBay or Paypal address. Please make sure your eBay and Paypal address is correct before you pay Shipping PolicyWe ship to your eBay or Paypal address. Please make sure your eBay and Paypal address is correct before you pay. Items will be shipped within 1-3 business day when we received payment. Delivery time depends on destination and other factors; International buyers please note: Import duties, taxes and charges are not included in the item price or shipping charges. These charges are buyer’s responsibility. We will try our best to reduce the risk of the custom duties. Custom Duties & Taxes: Import duties, taxes, and charges are not included in the item price or postage cost. These charges are the buyer’s responsibility. Ship to Europea under 160 Euro will used our IOSS number for VAT , over 160 Euro please offer your VAT number after your paid , Ship to South American please offer your RUC/NIT Number before shipment Country/Region of Manufacture:CHINA Point of origin:CHINA SHANGHAI Logistics mode: according to the logistics policy Returns Policy No reason to return or exchange within 30 days,The freight shall be borne by the seller Once your return has been received by the warehouse and it complies with our returns policy, we will refund you by your original payment method. Please be aware that payments can take up to 7 working days to process depending on your bank or payment provider. Returned items will be refunded excluding the original cost of shipping. After we have issued the refund, it will take up to 3 business days for the funds to be placed back on your credit card or Paypal account.About usCopyright © 2021 Dianxiaomi